Automated Nucleic Acid Workstation LT-ANW101

Automated Nucleic Acid Workstation LT-ANW101

Automated Nucleic Acid Workstation LT-ANW101 is designed with rotary nucleic acid extraction technology. Provided with high performance of specific nucleic acid extraction kits. Ensure stable and reliable test results with reagents and consumables. Workstation combines sample loading, nucleic acid extraction and PCR setup to achieve the automated operation of the whole process. It can be fitted with single strip reagent and number of extraction pores can be freely selected from 3 to 6. Construction of the PCR system of 96 samples can be completed within 70 minutes. Features automatic scanning and scientific management of sample information.

Specifications

Sample Throughput 1 to 96
Features Automatic scanning and identification of sample information+ nucleic acid extraction + PCR system setup
Principle The principle of magnetic bead method, and the technology of rotational mixing
Detectability 192 assays can be completed per run, with 4 different systems of PCR-setup simultaneously
Specimen Types Samples of plasma, serum, whole blood, swab solution, and urine, etc
Sample Loading Channels 44652
Pipetting Performance 15μL and below: accuracy: A≤2%, repetitive CV ≤ 3.0%;
15-50μL: accuracy: A≤1.5%, repetitive CV≤1.5%;
50μL and above: accuracy: A≤1.0%, repetitive CV≤1.2%;
Liquid Level Detection Capacitive-sensing level detection; pressure-sensing level detection
Sample Tube Specifications Compatible with a wide range of sample collection tubes, 1.5mL and 2.0mL centrifuge tubes, cryopreservation tubes and sample cups
Extraction Temperature Control Module 2 steps: pyrolysis & elution
with temperature control from 35 to 120°C
Visual Inspection Technology Real-time inventory status monitoring of consumables and reagents
PCR Reagent Chamber Light-proofing design; automatic cooling on start-up (4 ºC to 15 ºC refrigerator)
PCR Supplies/Consumables Compatible with 0.1mL and 0.2mL 8-tube strips, and 96-well plates;
Contamination Control Design (1) Separate, enclosed nucleic acid extraction space, with directional top ventilation to create an internal negative pressure system
(2) Sample loading device equipped with airtight, drip-proof design
(3) External droplet capture tray;
(4) UV light sterilization units for the experimental and extraction cabinets;
(5) Customized function: bottom ventilation of the nucleic acid extraction area available by special ventilation circuit design
Information technology (1) Multiple sample barcodes are scanned one by one during sample rack loading
(2) Identification of the extraction kit barcode, and automatic parsing of the extraction program information
(3) Identification of PCR kit component barcode, and automatic parsing of amplification program information
(4) Automatic parsing of PCR information and LIS connection, based on nucleic acid extraction data
Operation Embedded 12-inch touch screen; multi-module real-time status light
Size (W×D×H) 1370×810×890 mm
Weight 220 Kg
Power AC 220± 20 V, 50/60 Hz

Features

  • Visualized automatic test technology of material information
  • Accurate liquid transfer technology
  • Fast and high flux
  • Accurate and reliable
  • User friendly and fully automatic
  • 4 PCR reaction systems can be set up simultaneously
  • Features one key operation modularization of experimental flow
Application

It is widely applied in the field of immunoprecipitation, nucleic acid extraction of HBV, HCV, Flu viruses, HPV and SARS-CoV-2

Nucleic Acid Extractor System 

Labtro Nucleic Acid Extractor System are designed for efficient extraction of DNA and RNA.These are engineered with selective technology to prevent cross-contamination, ensuring reliable and accurate results. These system features a user-friendly interface for streamlined operation and monitoring. Our Nucleic Acid Extractor System are ideal for research and clinical applications requiring reliable nucleic acid purification.

Nucleic Acid Extractor System LT-NAE301

  • Sample Throughput : 1 to 96
  • Processing Volume : 30 to 1000 μL
  • Recommended Sample Volume : 200 μL

Nucleic Acid Extractor System LT-NAE302

  • Sample Throughput : 1 to 32
  • Processing Volume : 30 to 1000 μL
  • Magnetic Bead Residue : <1%
Nucleic Acid Extractor System LT-NAE303
  • Sample Capacity : 1 to 32
  • Sample Volume : 50 to 1000uL
  • Elution Volume : >95%

Fully Automated Nucleic Acid Extractor

Labtro Fully Automated Nucleic Acid Extractor enhances efficiency in DNA and RNA extraction. Their compact design allows for easy integration into any lab workspace. These system supports high-throughput processing with a capacity for up to 96 samples. Their user-friendly interface ensures consistent and reliable results across various applications. Our Fully Automated Nucleic Acid Extractor are ideal for molecular biology and clinical laboratories.

Fully Automated Nucleic Acid Extractor LT-FNW201
  • Processing volume : 30 to 1000
  • Sample throughput : 1 to 96
  • Magnetic beads recovery rate : >95%